IN Brief:
- The EC-C80-S400 and EC-C48-S400 inverters deliver maximum power outputs of 30kW and 17.5kW respectively.
- Both inverters support continuous output currents of 150A and maximum currents of 400A.
- The ED-EH130 integrates a permanent magnet motor, inverter, and hydraulic gear pump within a 48V assembly.
Danfoss Power Solutions has introduced two motor inverters and an integrated electrohydraulic powerpack within its Editron low-voltage electrification portfolio, expanding the power conversion options available to manufacturers of forklifts, mobile elevating work platforms, and other compact electric machinery.
The Danish manufacturer unveiled the EC-C80 and EC-C48 inverters alongside the ED-EH130 electrohydraulic assembly ahead of Bauma China in Shanghai. The additions extend its 80V and 48V portfolios, which encompass electric motors and power conversion systems for traction and hydraulic applications.
The EC-C80-S400 delivers 11.8kW continuously and up to 30kW, while the EC-C48-S400 provides continuous power of 7.5kW and a maximum of 17.5kW. Both inverters support continuous output currents of 150A, rising to a maximum of 400A, and carry an IP65 ingress protection rating.
The two voltage configurations accommodate different powertrain requirements without substantially changing the current ratings of the conversion electronics. Although the 80V device provides greater output power, the surrounding electrical architecture must also accommodate its operating voltage, including the battery configuration, switching components, protection devices, and associated motor windings.
Low-voltage power electronics must handle relatively high currents to deliver the power required by industrial machinery. Resistive losses increase with the square of the current passing through semiconductor devices, busbars, conductors, and electrical connections. Increasing the current capacity of the inverter consequently places additional demands on its internal thermal design and the components connecting it to the wider powertrain.
Danfoss specifies conversion efficiency of up to 97% for the inverters. Actual losses will vary according to the operating point, switching conditions, and characteristics of the connected motor, making peak efficiency distinct from the energy consumption experienced across a complete machine operating cycle.
The difference between continuous and maximum power ratings is particularly important in material handling equipment. A forklift accelerating with a load, for example, may require substantial torque for a relatively short period, while maintaining much lower power consumption during steady movement. A lifting mechanism can present similarly intermittent electrical loads.
The duration and frequency of these operations determine how much heat accumulates within the inverter and motor. Electrical components must accommodate the corresponding transient currents, while cooling arrangements must be capable of removing heat at the rate associated with repeated operating cycles. Maximum output alone cannot establish the powertrain’s ability to sustain a particular working pattern.
Danfoss’ third addition, the ED-EH130 ePowerpack, incorporates power conversion electronics into an integrated hydraulic power source. The 48V assembly combines an interior permanent magnet motor, inverter, and hydraulic gear pump, delivering continuous hydraulic power of up to 4kW and a maximum of 5kW.
The unit accommodates pump displacements between 3 and 8 cubic centimetres per revolution, with a continuous pressure rating of 250 bar and a maximum of 280 bar. It carries an IP67 ingress protection rating, addressing installation conditions in which electronic and electromechanical equipment may be exposed to water or contamination.
Integrating an electric motor and inverter with a hydraulic pump allows the flow supplied to hydraulic circuits to be adjusted through electrical motor control. Instead of relying on a mechanically driven pump operating whenever an engine is running, an electrified machine can control pump operation according to the hydraulic requirements of its individual functions.
Hydraulic output remains constrained by the relationship between pressure, flow, and available motor power. Operating a pump at its highest pressure does not necessarily permit its highest flow rate simultaneously, while the efficiency of the hydraulic and electrical components determines how much energy must be supplied by the battery.
Combining the three components also changes the packaging requirements of the hydraulic power system. Equipment manufacturers can incorporate the assembly without independently mounting and connecting a separate motor and inverter, although the installation must still accommodate hydraulic connections, electrical protection, heat dissipation, and access for maintenance.
Danfoss reports that more than 10,000 existing Editron systems are installed in scissor lifts. The new inverter ratings and integrated hydraulic assembly broaden the electrical configurations available to manufacturers developing further compact machinery around 48V and 80V architectures.