IN Brief:
- Cambridge-based Clarity Sensors has received a £1.9m NIHR award for a three-year photon-counting CT detector development programme.
- The PICASO project will combine perovskite semiconductor sensors with STFC's HEXITECMHz readout electronics.
- The partners aim to validate a complete detector module while establishing pilot-scale sensor production and quality management controls.
Clarity Sensors has secured a £1.9 million research and development award to advance perovskite semiconductor detectors for photon-counting computed tomography, working with the Science and Technology Facilities Council (STFC) on the associated readout electronics.
The funding comes from the National Institute for Health and Care Research (NIHR) through its Invention for Innovation programme. Clarity Sensors will receive £1.3 million as project lead, with the remainder supporting work by STFC’s Technology Department.
The three-year programme, known as PICASO, began on 1 October 2026. Its funding and technical objectives were disclosed by Cambridge Enterprise on 19 November.
The collaboration will develop a complete detector module combining Clarity Sensors’ halide perovskite semiconductor material with STFC’s HEXITECMHz readout technology. The partners aim to progress the system from Technology Readiness Level 3 to Level 6 through engineering development and testing in a preclinical environment relevant to CT imaging.
Photon-counting CT differs from conventional X-ray detection by measuring individual incoming X-ray photons and collecting information about their energies.
In a conventional integrating detector, incident X-ray energy is accumulated to produce a measurement associated with the intensity reaching the detector. A photon-counting arrangement instead detects individual events, allowing the resulting data to be divided according to photon energy.
That additional information can help distinguish materials with different X-ray attenuation characteristics. It can also support improvements in image resolution and the management of radiation exposure, depending on the detector design and the complete imaging system.
Commercial photon-counting CT equipment already exists, but the semiconductor materials used in many systems are difficult and expensive to manufacture.
Cadmium telluride and cadmium zinc telluride are established detector materials. Their production involves specialised crystal growth and processing, with demanding requirements for material quality, detector uniformity, and manufacturing yield.
Cambridge Enterprise reports that suitable crystals can take months to grow at temperatures exceeding 750°C. Only a limited number of suppliers can produce material meeting the requirements of medical imaging systems.
Clarity Sensors is developing an alternative based on halide perovskite single crystals. The company says these can be grown at approximately 40°C over a period of days, providing a different manufacturing route from established cadmium-based detector materials.
Lower-temperature growth and shorter processing times offer potential manufacturing advantages, but they do not by themselves establish the cost, yield, or reliability of a completed medical detector.
Semiconductor material must perform consistently when incorporated into a device containing electrical contacts, readout electronics, and mechanical packaging. Variations in material composition, crystal quality, electrical leakage, and operating stability can affect detector performance.
Clarity Sensors reports laboratory results comparable with existing cadmium telluride devices on selected detector measurements. It has also demonstrated operation under X-ray flux and electrical bias conditions relevant to CT.
Those results are an intermediate development milestone. The new programme must establish whether the performance can be maintained within a complete detector module and across the operating conditions required for its intended application.
The readout electronics are central to that work. When an X-ray photon interacts with the semiconductor, the resulting electrical charge must be detected, measured, and associated with the relevant sensing element.
STFC’s HEXITECMHz technology is designed to capture energy-resolved detector information at a continuous frame rate of one million frames per second.
That figure describes the readout technology’s operating capability, not the clinical image acquisition rate of a finished CT scanner.
Integrating the readout chip with a new sensor material requires control over electrical connections, detector geometry, signal noise, and the relationship between incoming photon energy and the measured electronic response.
The partners will adapt HEXITECMHz for the perovskite sensors before building and validating the complete module.
Detector performance must be evaluated at flux levels relevant to CT. High photon rates can create demands involving event separation, electronic processing, and the accurate measurement of energy when signals arrive close together.
Electrical leakage and noise also affect the ability to detect individual events. Materials with suitable resistivity and charge-transport characteristics can help preserve the distinction between a genuine photon signal and unwanted electrical activity.
Clarity Sensors’ work addresses those material properties alongside the practical requirements of manufacturing and assembling detector devices.
The company intends to establish pilot-scale sensor production at its Cambridge facility during the programme. It will also introduce quality management controls aligned with relevant ISO 13485 requirements for medical device manufacturing.
The intention to establish such controls should not be confused with certification of the finished detector or regulatory approval for clinical use.
Clarity Sensors was established in 2022 from research associated with Professor Sam Stranks’ group at the University of Cambridge. Earlier support included £210,000 from Cambridge Enterprise’s Technology Investment Fund and a separate European Innovation Council Transition grant.
The PICASO award provides funding for the next phase of detector development, bringing semiconductor material engineering together with high-speed electronic readout and application-specific verification.
The project is scheduled to run for 36 months from October 2026. Commercial manufacturing volumes, finished detector pricing, and clinical approvals have not been announced.