RECOM extends desktop power supply portfolio

RECOM extends desktop power supply portfolio

RECOM has expanded its portfolio of external AC/DC power supplies. The RACA100 and RACA150 series deliver 100W and 150W respectively, supporting industrial and medical applications with conversion efficiencies reaching 92.5%.


IN Brief:

  • Both series accommodate AC input voltages between 90V and 264V, with 12V and 24V DC output options.
  • Typical full-load conversion efficiencies reach 90.5% and 92.5% for the 100W and 150W series respectively.
  • The supplies incorporate two means of patient protection and support Class I and Class II equipment configurations.

RECOM has expanded its external AC/DC power supply portfolio with the RACA100 and RACA150 series, introducing two families of desktop adapters for industrial and medical electronic equipment, with typical conversion efficiencies reaching 92.5%.

Rated at 100W and 150W respectively, the supplies accommodate AC input voltages between 90V and 264V and are available with nominal DC outputs of 12V or 24V.

Both families occupy a footprint of 155 × 75mm, with the RACA100 measuring 25.4mm in height and the RACA150 measuring 28.5mm. RECOM specifies an operating temperature range of −30°C to +70°C, with output power derating required above +40°C.

The 12V RACA150 provides a rated output current of 12.5A, while its 24V counterpart delivers 6.25A. Typical conversion efficiencies at full load, measured with a 230V AC input at an ambient temperature of +25°C, reach 90% and 92.5% respectively.

These differences influence the thermal requirements of the power conversion system. At its rated output, a supply operating at 90% efficiency dissipates approximately 16.7W, compared with around 12.2W at 92.5% efficiency. Accommodating those losses within a relatively compact enclosure requires coordination between semiconductor selection, magnetic component design, PCB layout, and the thermal characteristics of the housing.

Locating mains voltage conversion outside the electronic equipment allows manufacturers to allocate more internal space to processors, sensing circuitry, communications hardware, and other application-specific components. It can also reduce the amount of heat generated within the equipment enclosure, although subsequent DC/DC conversion stages may still be required to provide regulated supplies to individual electronic subsystems.

Both RECOM families incorporate active power factor correction, which addresses the relationship between mains voltage and the current drawn by the power supply.

In conventional rectifier circuits, energy storage capacitors can draw disproportionately large currents near the peaks of the AC waveform. The resulting distortion increases harmonic content and can raise the RMS current required to deliver a particular amount of useful power.

Active correction uses controlled switching circuitry to shape the input current. Its implementation reduces harmonic distortion while introducing additional switching and magnetic losses that must be considered within the overall conversion efficiency.

RECOM specifies a maximum no-load consumption of 0.15W and identifies both families as meeting the US Department of Energy’s Level VI and Level VII efficiency limits. No-load consumption is particularly relevant to equipment that remains connected to the mains for extended periods while inactive or disconnected from its external adapter.

Medical applications introduce additional requirements relating to electrical isolation and leakage currents. The RACA100 and RACA150 incorporate two means of patient protection (2MOPP) under the medical electrical equipment safety framework and meet specified Type BF leakage current limits.

The supplies can be configured with IEC C14 mains inlets for Class I equipment or IEC C8 inlets for Class II applications. Class I protection relies on protective earthing alongside insulation, whereas Class II construction provides double or reinforced insulation without depending on a protective earth connection.

Although selecting an appropriately certified supply can simplify elements of medical equipment development, the electrical safety of the completed device depends on its overall architecture. Patient connections, communications interfaces, internal power distribution, and accessible conductive surfaces must all be considered when assessing leakage currents and protection against electrical faults.

The output voltage selection also affects the design of the connection between the adapter and equipment. Transmitting 150W at 12V requires twice the current needed at 24V. For a given cable resistance, doubling the current quadruples resistive losses, increasing the importance of cable dimensions, connector contact resistance, and thermal performance.

RECOM offers different output connector arrangements, together with integrated protection against short circuits, excessive loads, and elevated temperatures. Both product families carry a three-year warranty.

The introduction extends RECOM’s external power conversion range alongside its existing industrial and embedded products, including the 300W isolated DC/DC converters recently added to its industrial portfolio.


Stories for you


  • RECOM extends desktop power supply portfolio

    RECOM extends desktop power supply portfolio

    RECOM has expanded its portfolio of external AC/DC power supplies. The RACA100 and RACA150 series deliver 100W and 150W respectively, supporting industrial and medical applications with conversion efficiencies reaching 92.5%.


  • DigiProces invests €2m in electronics manufacturing

    DigiProces invests €2m in electronics manufacturing

    DigiProces will invest €2m at its principal Spanish manufacturing facility. The programme will strengthen electronics production, quality assurance, and factory infrastructure to accommodate the requirements of aerospace and defence customers.