IN Brief:
- Silicon Creations has demonstrated four communication protocols using a common SerDes physical medium attachment.
- The platform combines controller IP from Rambus, Comcores, Trilinear Technologies, and Chip Interfaces.
- Live demonstrations establish individual protocol operation, providing a reference for reusing physical interface IP across semiconductor designs.
Silicon Creations has demonstrated four industry-standard communication interfaces using a common serializer-deserializer physical medium attachment, providing a hardware reference for integrating different controller technologies with the same high-speed semiconductor interface.
The demonstration combines Silicon Creations’ SerDes physical medium attachment (PMA) with production controller IP from Rambus, Comcores, Trilinear Technologies, and Chip Interfaces. It supports PCIe Gen4, 10GBASE-R Ethernet, DisplayPort, and JESD204B, with connections to external hardware used to validate each interface.
The platform was introduced on 12 November and will be demonstrated at semiconductor industry events in Beijing and Munich during November. Its purpose is to show how one physical interface architecture can support several established communication standards without requiring a separately developed PMA for each application.
Modern systems-on-chip frequently incorporate multiple high-speed interfaces to communicate with processors, displays, networking equipment, and data converters. These connections perform different functions, but their electrical implementations can share underlying requirements for high-speed serial transmission and reception.
A SerDes converts parallel data into a serial stream for transmission and reconstructs the information at the receiving end. Its physical circuitry must generate, transmit, recover, and interpret electrical signals within the timing and signal integrity requirements of the selected interface.
The PMA performs functions associated with that physical signalling, while the protocol controller handles the data structures, link management, and other behaviour defined by the relevant communication standard. Integrating the two requires more than confirming that both blocks support a nominal data rate.
Clocking, link training, electrical characteristics, and error handling must operate correctly across the controller and physical interface. A mismatch can prevent a connection from establishing successfully or create data transmission errors even when the constituent IP blocks function independently.
Silicon Creations has assembled its demonstration around a multiprotocol SerDes test chip connected to an HTG board containing an AMD FPGA. The FPGA hosts the four partner controllers, while custom interface boards connect the PMA to external equipment.
A PC-based dashboard controls the system and displays connection status, receiver eye information, and transmission error measurements. The platform cycles between the different protocols, allowing their operation to be examined through the same physical interface hardware.
The PCIe Gen4 configuration uses a controller supplied by Rambus. It demonstrates link training at up to 16 gigatransfers per second on one lane, with the connection verified through a Rambus PCIe FPGA validation board.
PCIe uses link training to establish operating conditions between connected devices. The process coordinates capabilities and communication parameters before normal data transfers begin. Demonstrating this interaction through the common PMA establishes that the physical interface can support the selected controller’s PCIe Gen4 operation.
For Ethernet, a controller developed by Denmark-based Comcores establishes a 10GBASE-R connection operating at 10.3125 Gbit/s. The signal passes through an optical SFP+ module to a commercial 10G Ethernet switch, while traffic generation and checking functions monitor data transfer and transmission errors.
The Ethernet configuration tests the interface through external networking equipment rather than relying exclusively on an internal loopback. This provides evidence of compatibility between the controller, PMA, optical interface, and receiving hardware under the demonstrated operating conditions.
DisplayPort operation uses controller IP from Trilinear Technologies. The system performs link training and transmits video test patterns to a conventional monitor, with connection status displayed through the demonstration interface.
Display interfaces impose their own signalling and training requirements, while the controller must manage the transmission of video information according to the protocol. The demonstration establishes operation with the selected external monitor but does not provide a comprehensive compliance assessment across every DisplayPort configuration.
The fourth interface uses JESD204B controller IP from Chip Interfaces. Its transmit and receive paths operate at 10 Gbit/s, with FPGA-generated data passing through a digital-to-analogue converter, analogue loopback, and analogue-to-digital converter operating at 500 MSPS.
JESD204 interfaces are used to connect high-speed data converters with digital processing hardware. Their implementation must account for data transmission rates, timing relationships, and the requirements of the converter system.
The demonstrated connection uses JESD204B. Although the underlying controller technology also supports JESD204C, the published test configuration does not establish a separate JESD204C hardware demonstration.
The platform incorporates error injection for Ethernet, DisplayPort, and JESD204B. Deliberately introducing errors allows the monitoring system to demonstrate how transmission faults are detected and counted. An integrated eye monitor also provides information about the receiver signal opening during operation.
These functions support engineering evaluation, although the company has not published a comprehensive set of measured bit error rates, electrical margins, or comparative signal integrity results for all four configurations.
The distinction between switching protocols and operating them simultaneously is important. Silicon Creations demonstrates each supported interface using the common PMA, rather than showing four independent protocols running concurrently through one serial lane.
The company’s wider multiprotocol architecture supports data rates from below 100 Mbit/s to 32 Gbit/s and additional interfaces including USB 3.x, several Ethernet variants, embedded DisplayPort, Interlaken, and CPRI. Implementations are offered across semiconductor manufacturing processes from TSMC, GlobalFoundries, Samsung, and UMC.
Reusing physical interface IP across different products can reduce duplicated design and validation effort, particularly when semiconductor developers need several communication standards across a common product family. Each implementation still requires controller integration, physical design, timing verification, and compliance testing appropriate to its intended operating conditions.
The demonstration establishes practical operation between one PMA and four independently supplied controller implementations. Its application to commercial semiconductor designs will depend on the required protocols, manufacturing process, electrical specifications, and integration constraints of each device.