Phoenix Contact expands compact signal conditioning range

Phoenix Contact expands compact signal conditioning range

Phoenix Contact has expanded its compact industrial signal conditioning portfolio. Three additions to the MINI Analog Pro family address temperature measurement, isolated controller outputs, and the integration of current-based instrumentation with voltage inputs.


IN Brief:

  • Three signal conditioning devices incorporate electrical isolation within individual 6.2mm-wide modules.
  • The output conditioner maintains HART communications between control equipment and field instrumentation.
  • A repeater power supply converts 4–20mA field signals into isolated voltage outputs.

Phoenix Contact has expanded its MINI Analog Pro signal conditioning family with three devices addressing temperature measurement, analogue output isolation, and the integration of powered field instrumentation with voltage-based control systems.

Presented at SPS 2026 in Nuremberg, Germany, the modules retain the existing product family’s 6.2mm width while incorporating three-way electrical isolation between their input, output, and power supply circuits.

The additions comprise the MINI MCR-2-T-I temperature measuring transducer, MINI MCR-2-IDS-I-I output signal conditioner, and MINI MCR-2-RPS-I-U repeater power supply, with screw and push-in connection options available.

The temperature measuring transducer supports resistance temperature detectors (RTDs), thermocouples, and linear resistive sensing elements, converting their respective electrical signals into a standardised analogue output. Configuration is supported through Phoenix Contact’s engineering software and associated mobile tools.

Although RTDs and thermocouples both measure temperature, their electrical characteristics require substantially different signal processing arrangements. RTDs exhibit a temperature-dependent resistance, which must be measured by applying an excitation signal and determining the resulting electrical response.

Thermocouples generate a small voltage associated with the temperature difference between junctions of dissimilar metals. Measurement circuits must account for the temperature of the reference junction, alongside amplifying and interpreting the comparatively low-level signal generated by the sensing element.

Converting these measurements into a standard current signal allows industrial controllers to receive temperature information without incorporating separate measurement circuitry for each sensor technology. Current-based instrumentation is particularly useful where sensors are separated from control equipment by substantial cable distances, as variations in cable resistance have less direct influence on the transmitted measurement, provided the circuit maintains sufficient voltage to drive the required current.

Phoenix Contact’s output signal conditioner addresses communication in the opposite direction, transferring analogue current commands of 0–20mA or 4–20mA from controllers to field equipment such as actuators and positioners.

The module maintains compatibility with Highway Addressable Remote Transducer (HART) communication, allowing digital information to pass through the conditioning interface alongside the principal analogue signal.

HART uses frequency-shift keying to superimpose digital communications on the analogue current loop. Equipment can exchange configuration information, device identification, and diagnostic data without replacing the underlying current-based control architecture.

An isolation device that reproduces only the low-frequency analogue quantity may prevent this additional information from reaching its destination. HART-transparent conditioning therefore requires the interface to accommodate the associated communication frequencies while maintaining accurate transmission of the principal control signal.

Phoenix Contact’s third addition provides an isolated voltage output from field instrumentation operating on a 4–20mA current loop. The repeater power supply energises the connected transmitter and converts its measurement signal into either a 0–10V or 2–10V output.

This arrangement supports integration with equipment that accepts voltage-based analogue inputs but lacks the circuitry required to power and interpret a current-loop transmitter directly. It also allows established instrumentation to remain in service when changes are made to the associated control equipment.

Electrical isolation separates the respective circuit domains within each module, reducing the potential for unwanted current paths arising from differences in electrical potential between interconnected equipment.

These differences can become particularly pronounced in installations containing independently powered machinery, distributed control cabinets, and instrumentation connected across extensive production facilities. Ground potential differences can introduce measurement errors or interfere with communications where equipment shares conductive signal paths.

The compact module dimensions also address the physical constraints of industrial control cabinets, where substantial numbers of conditioning devices may need to be installed alongside controllers, power supplies, communications equipment, and protective components.

Shared power distribution through compatible DIN rail infrastructure reduces the number of individual supply connections required within the enclosure, while retaining the ability to select different conditioning functions for individual circuits.

The expanded MINI Analog Pro family consequently accommodates a wider range of instrumentation interfaces within a consistent mechanical and electrical architecture, allowing temperature measurement, isolated controller outputs, and powered field transmitters to be integrated without introducing separate module formats for each application.


Stories for you


  • PCB material shortages increase LED display costs

    PCB material shortages increase LED display costs

    Rising PCB material costs are increasing LED display manufacturing expenses. TrendForce estimates that four-layer PCB prices have risen by 10–15% during the fourth quarter, affecting several established display module architectures.


  • Kioxia advances flash storage for GPU memory expansion

    Kioxia advances flash storage for GPU memory expansion

    Kioxia has developed faster flash storage for demanding GPU workloads. Its GP2 solid-state drive incorporates third-generation XL-FLASH technology, delivering more than 18 million random read operations per second under specified conditions.