HMS introduces reusable industrial Ethernet connectivity platform

HMS introduces reusable industrial Ethernet connectivity platform

HMS Networks has introduced a reusable industrial Ethernet connectivity platform. Anybus ONE combines multiple industrial network protocols, embedded security, and configurable host interfaces within an architecture designed for integration across device portfolios.


IN Brief:

  • The initial Anybus ONE system-on-module supports PROFINET, EtherNet/IP, and EtherCAT.
  • Its 26 × 26mm architecture incorporates dedicated application processing alongside industrial network functionality.
  • Secure provisioning, signed firmware, and device identity management address industrial product lifecycle requirements.

HMS Networks has introduced Anybus ONE, an embedded industrial connectivity platform enabling equipment manufacturers to integrate multiple industrial Ethernet protocols using a common hardware and software architecture.

The first product within the platform, the Anybus ONE-S100-31-10, supports PROFINET, EtherNet/IP, and EtherCAT within a compact 26 × 26mm system-on-module (SoM). The module is accompanied by Anybus Studio, a configuration environment for developing and maintaining industrial device connectivity.

HMS has designed the platform to reduce the network-specific development required within the host application, allowing manufacturers to reuse connectivity implementations across different equipment variants.

Industrial automation devices frequently operate within communications architectures determined by the wider machinery installation. Although several industrial protocols use Ethernet physical interfaces, differences in protocol behaviour, data representation, timing, and configuration can require substantial changes to embedded firmware.

Anybus ONE separates industrial network processing from equipment application functions. Its architecture incorporates dedicated communications processing alongside an Arm Cortex-M7 application core operating at frequencies of up to 800MHz.

Available host interfaces include Serial Peripheral Interface (SPI), UART, general-purpose input/output (GPIO), and Modbus RTU. Different interfaces accommodate combinations of cyclic process data, parameters, commands, and discrete signals according to the requirements of the host design.

Separating network processing from application functionality can simplify the implementation of equipment such as sensors, motor drives, instrumentation, and industrial controllers. Rather than incorporating each network protocol directly into the principal application firmware, manufacturers can establish a common representation of equipment parameters and operating information, with the network module managing the corresponding external communications.

A temperature measurement device, for example, may need to make measured values, diagnostic information, configuration parameters, and alarm states available to a programmable logic controller. Although the underlying measurement functionality remains unchanged, the mechanisms through which different industrial networks represent and exchange these quantities can vary considerably.

A common host interface enables more of the measurement application to remain consistent between network variants, reducing the extent to which differences in communications requirements affect the underlying device firmware.

HMS’s Anybus Studio configuration environment provides graphical tools for defining these relationships. Its development documentation describes workflows for establishing host interfaces, selecting parameters and data sets, configuring network-specific representations, and producing the files required for equipment integration.

Within a PROFINET implementation, the configuration can map host data into the module and submodule structure expected by the external control system. Device description files generated alongside the configuration support integration into compatible industrial engineering environments.

The platform also incorporates security capabilities addressing increasingly complex requirements for connected industrial devices, including device identity management, certificate handling, secure provisioning, and digitally signed firmware updates.

Cryptographic verification of firmware enables equipment to check the authenticity of software before accepting an update. Device identities and associated credentials can establish trusted relationships between equipment and external systems, reducing dependence on shared authentication information across large device populations.

These mechanisms are increasingly relevant as industrial equipment manufacturers prepare for the EU Cyber Resilience Act, which introduces cybersecurity requirements and lifecycle responsibilities for products containing digital elements.

HMS has designed the module with IEC 62443-4-2 and Cyber Resilience Act requirements in mind, supported by software bill of materials information. The host application and its wider interfaces remain part of the completed product’s security architecture, alongside the network functionality provided by the module.

Long industrial equipment lifecycles also place greater emphasis on maintaining communications software after initial deployment. Separating this functionality from the principal equipment application can reduce the extent of host firmware changes associated with network maintenance and security updates.

The S100-31-10 is specified for operating temperatures from −40°C to +85°C, accommodating applications where electronics may be installed outside conventional temperature-controlled environments.

HMS intends to extend Anybus ONE into additional products based on the same architectural foundation. Consistency across future host interfaces could enable manufacturers to introduce new industrial communications capabilities while retaining a greater proportion of existing application firmware and hardware designs.


Stories for you


  • Kioxia advances flash storage for GPU memory expansion

    Kioxia advances flash storage for GPU memory expansion

    Kioxia has developed faster flash storage for demanding GPU workloads. Its GP2 solid-state drive incorporates third-generation XL-FLASH technology, delivering more than 18 million random read operations per second under specified conditions.


  • Powell expands high-voltage DC interconnect offering

    Powell expands high-voltage DC interconnect offering

    Powell Electronics has extended its European high-voltage interconnect product portfolio. Glenair’s kV Seal contact assemblies accommodate DC operating voltages up to 22kV within compatible established connector architectures.