IN Brief:
- Saelig has extended commercial availability of Aaronia's XPS-WR waveguide power sensors.
- Eight sensor models cover frequencies from 60GHz to 1.1THz through band-specific waveguide interfaces.
- USB connectivity and RTSA Suite PRO software support computer-controlled RF measurements.
Saelig has extended commercial availability of the XPS-WR waveguide power sensor family manufactured by Germany’s Aaronia, providing eight instruments for continuous-wave measurements across frequencies from 60GHz to 1.1THz. The distributor’s latest rollout gives RF engineers access to sensors covering millimetre-wave and terahertz applications, including transmitter evaluation, oscillator characterisation, and laboratory calibration work.
The equipment was already presented by Aaronia at European Microwave Week in London during October 2026. The November development concerns Saelig’s commercial distribution of the sensor range rather than the original introduction of the measurement technology.
The XPS-WR family uses separate models with waveguide interfaces appropriate to different frequency bands. The XPS-WR12 covers 60–90GHz, while the XPS-WR10 operates from 75GHz to 110GHz. The XPS-WR6.5 extends measurement capability from 110GHz to 170GHz, followed by the XPS-WR5.1 covering 140–220GHz.
Four additional models address higher frequencies. The XPS-WR3.4 covers 220–330GHz, the XPS-WR2.2 operates from 330GHz to 500GHz, and the XPS-WR1.5 covers 500–750GHz. The XPS-WR1.0 completes the family with a frequency range extending from 750GHz to 1,100GHz.
The individual instruments employ waveguide connections matched to their operating bands, rather than a single broadband RF input covering the entire frequency range. This reflects the physical characteristics of waveguides, whose dimensions determine the frequencies and propagation modes they can support.
At lower radio frequencies, coaxial connectors and cables provide widely used methods of transferring signals between test equipment and devices under evaluation. At millimetre-wave and terahertz frequencies, transmission losses and mechanical tolerances become increasingly demanding, making suitable waveguide interfaces important to the measurement arrangement.
Waveguides carry electromagnetic energy within a defined structure. Their geometry determines the supported propagation conditions, while the dimensions and alignment of connections influence transmission losses and reflections. Choosing the correct interface is therefore part of obtaining a useful measurement, rather than simply a mechanical connection decision.
The XPS-WR sensors are designed for continuous-wave power measurements. These involve determining the power of an RF signal that remains present over the relevant measurement interval, such as the output of a laboratory oscillator or an unmodulated transmitter.
This function differs from analysing a signal’s spectrum, demodulating transmitted information, or characterising rapid pulses. Although those measurements may also be required during RF development, they need appropriate equipment and should not be assumed to be capabilities of the XPS-WR power sensors.
Saelig identifies transmitter testing, oscillator-based reference measurements, and RF source calibration among the intended applications. In each case, the measurement system must be suited to the expected frequency, power level, and accuracy requirements.
The sensors can connect directly to a computer through USB and operate using Aaronia’s RTSA Suite PRO software. They can alternatively be connected to the manufacturer’s Power Meter base station for direct display of measurement results.
Computer-based operation allows the instruments to be incorporated into laboratory procedures where measurements are collected, displayed, and recorded through software. Automated testing can be useful when a source must be evaluated repeatedly across different operating conditions, although the complete test arrangement still requires suitable control and calibration.
The sensors also incorporate stored calibration information, according to published product documentation. Calibration characteristics are important because the measured electrical response must be related to the RF power delivered to the instrument under the specified conditions.
At higher frequencies, measurement uncertainty may be influenced by losses in waveguide sections, adapters, attenuators, and other components between the signal source and sensor. Small mechanical differences can also affect repeatability, particularly where measurement fixtures are disconnected and reassembled.
A sensor’s nominal frequency coverage consequently establishes only part of its suitability for a particular test. Engineers must also consider its measurable power range, calibration uncertainty, connection geometry, and the requirements of the complete measurement procedure.
The increasing use of high-frequency electronics in communications research, radar, and scientific instrumentation has created applications requiring measurement capabilities above those supported by many conventional RF instruments. The XPS-WR range addresses continuous-wave power characterisation across several of these frequency bands without combining all of them into one sensor.
Saelig describes the range as available to order through its distribution operation. The published announcement does not establish prices or delivery times for every model, and those details must be confirmed against the selected instrument.
The latest distribution development expands commercial access to Aaronia’s existing measurement technology. Selection of an individual XPS-WR model will depend on the required frequency band, measurement conditions, and laboratory interface rather than the 1.1THz upper limit of the family as a whole.