Sensirion releases downmount liquid flow sensors

Sensirion releases downmount liquid flow sensors

Sensirion has released two manifold-mounted sensors for precision liquid measurement. The SLF3S-0600D and SLF3S-1300D provide bidirectional flow measurements up to 2ml/min and 40ml/min respectively, allowing direct integration into compact fluidic assemblies.


IN Brief:

  • Sensirion's downmount SLF3x sensors are available globally for integration into fluidic manifolds.
  • The two variants offer maximum water flow measurements of 2ml/min and 40ml/min.
  • Direct manifold mounting reduces the need for external tubing and fittings within suitable equipment designs.

Sensirion has made two downmount liquid flow sensors globally available, extending its SLF3x range with a mechanical configuration designed for integration directly into fluidic manifolds used in analytical, diagnostic, and industrial equipment.

The SLF3S-0600D and SLF3S-1300D provide bidirectional flow measurements, with maximum water flow rates of 2ml/min and 40ml/min respectively. Their downmount connections allow the sensors to be incorporated into a compatible manifold without requiring the separate external tubing arrangements used in other configurations.

The change concerns the mechanical integration of an established sensing technology. Both variants use Sensirion’s CMOSens technology, which combines the sensor element and signal processing within a compact measurement assembly.

Small liquid flow rates must often be measured accurately in equipment that delivers reagents, manages samples, or controls fluid movement through analytical processes. Variations in flow can affect the volume transferred during a defined period, particularly where the equipment operates through repeated dispensing or measurement cycles.

In such systems, the sensing element forms one part of a fluidic arrangement that may also include pumps, valves, reservoirs, filters, and connecting channels. Its placement affects the mechanical design of the assembly and the route taken by liquid through the equipment.

The downmount SLF3x configuration allows the flow channel to connect directly with the manifold. This can reduce the number of individual joints required during assembly, although the manifold still needs an appropriate sealing arrangement and must maintain the intended fluid path.

External tubing provides flexibility during development and maintenance but also consumes space and introduces connections that must be assembled and inspected. A direct manifold connection can simplify compact equipment designs where the routing of liquid is largely fixed.

The sensors retain the straight, unobstructed flow channel associated with the SLF3x family. Measurement takes place without moving mechanical parts, avoiding the wear mechanisms found in some flow measurement systems that rely on rotating or displaced elements.

The two variants address different measurement ranges. The SLF3S-0600D provides a full-scale water flow rate of 2ml/min, while the SLF3S-1300D extends that limit to 40ml/min.

Selecting between them requires consideration of both the maximum expected flow and the measurement performance needed at lower rates. A device with a larger full-scale range does not automatically provide the best measurement resolution for an application operating predominantly at much smaller flows.

Sensirion specifies water measurement accuracy of 5% and repeatability of 0.5% for the SLF3S-0600D. Accuracy describes how closely the indicated result agrees with the actual flow under the specified conditions, while repeatability concerns the consistency of measurements obtained under comparable conditions.

The SLF3S-1300D also carries published water accuracy and repeatability specifications of 5% and 0.5% respectively. These values should be assessed alongside the relevant flow ranges, measurement conditions, and the media used in the application.

The smaller sensor’s published specifications include a maximum operating pressure of 12 bar and a supply voltage range of 3.2V to 3.8V. Its dimensions are 15 × 30 × 6.5mm.

Pressure limits apply to the sensor under defined operating conditions. They do not establish the allowable pressure of a complete fluidic instrument, where manifolds, seals, fittings, and other components may impose different limits.

The measurement assembly also requires electrical integration. Sensirion’s evaluation kits provide an I²C interface and supporting cabling, allowing the sensor to communicate with external control or data acquisition equipment.

The company specifies response times below 20ms for the evaluation configurations. Actual system response may also be affected by the sampling strategy, fluid movement, control software, and connected actuators.

Flow measurements can be used to monitor a process or form part of a feedback controller. Where a pump or valve is regulated according to measured flow, the control electronics compare the sensor output with the required operating condition and adjust the actuator.

The sensor itself does not determine how a pump responds. Stability and accuracy of a closed-loop system depend on the characteristics of the pump, the fluid path, the controller, and the measurement system working together.

Fluid compatibility is another practical consideration. The SLF3x family uses materials selected for chemical resistance, but the suitability of a particular liquid must be established against the manufacturer’s media specifications.

Water and isopropyl alcohol are among the liquids referenced in the product information. Other fluids may differ in thermal properties, viscosity, and chemical behaviour, affecting both sensor compatibility and the interpretation of measured flow.

Direct manifold mounting places additional importance on port alignment, mechanical tolerances, and sealing. Those requirements must be assessed during design and production, particularly where equipment is repeatedly cleaned or exposed to changing operating temperatures.

Sensirion supplies evaluation kits for both downmount variants, enabling equipment developers to assess electrical communication and fluidic integration before adopting a sensor in a production design.

The global availability of the SLF3S-0600D and SLF3S-1300D provides two defined measurement ranges within the same downmount architecture. Their application will depend on the required flow characteristics, fluid compatibility, electrical interface, and the mechanical design of the surrounding manifold.


Stories for you


  • EPC Space expands GaN transistor packaging options

    EPC Space expands GaN transistor packaging options

    EPC Space has expanded packaging choices for radiation-tolerant GaN transistors. Its 100–200V portfolio includes plastic QFN and hermetic options, providing different electrical, mechanical, and environmental configurations for satellite power conversion and aerospace equipment.


  • Samsung expands NVIDIA partnership into MLCCs

    Samsung expands NVIDIA partnership into MLCCs

    Samsung Electro-Mechanics has extended its semiconductor partnership with NVIDIA further. The companies have amended their substrate supply agreement and broadened cooperation involving high-reliability multilayer ceramic capacitors for accelerated computing platforms.